<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-21 22-06-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 68 kHz 8180 1,6381
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,7 dBr 4,85 dBr 5,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 17 kHz % above 76 kHz: 1,6381 Acquired: 2025/06/21 22.05.18 Total samples: 8180 Equivalent time: 0:06:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 5,5 dBr MIN: 3,7 dBr AVE: 4,85 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/06/21 22.05.18) 21.52 21.54 21.56 21.58 22.00 22.02 22.04 0 2 4 6 Pm [dBr]